Loading Bay Adviser

    Welcome to the Loading Bay Adviser by MHE.

    The Loading Bay Adviser offers recommendations for door and docking equipment that are required at the interface between vehicle and building.

    The following questions will guide you to the best suited products to equip your loading bay.







    Elevating dock levellers can be built in virtually any size and capacity required for the application.
    They provide the ability to service trucks at any height and can also offer fork trucks access to ground level.


    • Available in 30,000lbs (13.6t) or 50,000lbs (22.0t) capacity ratings as standard

    • Heavy-duty version up to 80,000lbs (36t) capacity available for the most demanding loading conditions

    • Heavy-duty I-beam under-deck support ensures high structural strength against rolling loads

    • Heavy-duty hydraulic system with high-quality power pack and cylinders from reputable manufacturers

    • Maintained tilt design compensates for uneven loading conditions

    • Standard working range +/- 12″ (+/- 300 mm) up/down, customisable if necessary to suit higher trucks or low loading docks

    • Fail-safe safety design

    • Weatherproof IP 55 control box

    • Standard working range toe guards supplied

    • Comes with one set of moulded rubber dock bumpers as standard


    Vertical Storing Dock Leveller is the perfect loading dock solution for facilities
    and applications that require strict climate control or high cleanliness levels.
    It improves internal temperature control, reduces the risk of door damage and minimises debris entry.




    TR IN

    For moderate-to-high traffic indoor or outdoor environments.
    • 1,500,000 operating cycles
    • 6,000 x 5,800 mm max size
    • Galvanised steel door structure & drive shaft

    TECHNICAL SPECIFICATION TR IN

    WIDTH (mm)

    2,000–6,000

    HEIGHT (mm)

    1,800–5,800

    OPENING SPEED (m/s)

    2.0 - size up to 3,000 x 3,000 mm
    1.5 - size up to 5,000 x 5,000 mm
    1.0 - size up to 5,800 x 6,000 mm

    CLOSING SPEED (m/s)

    0.8 or as opening speed

    FABRIC TYPE

    PVC coated polyester

    FABRIC WEIGHT (g/m2)

    900

    PANEL TYPE
    (OPTIONAL)

    Vision, 1 mm thick transparent PVC

    TRACK GUIDES

    Extruded polyethylene

    WIND LOAD

    EN12424:2000
    • Class 3 (3,000 x 3,000 mm)
    • Class 2 (5,000 x 5,000 mm)
    • Class 1 (5,800 x 6,000 mm)

    OPERATING TEMPERATURE RANGE (°C)

    • -15 to +70, indoor drive
    • -5 to +70, outdoor drive
    • -35 to +70, drive & side frame heating systems

    CONTROL UNIT

    • Painted steel housing, 470 x 290 x 200 mm
    • IP54 ingress protection; frequency converter

    OPERATOR

    Supply 240V/50–60Hz; 400V/50–60Hz; 1.5kW motor power
    • IP54 ingress protection
    • Limit positions by encoder

    SAFETY

    • Built to EU standards - EN 13241 CN
    • Photocells (1 pair), 500 mm from floor level
    • Door bottom safety sensor
    • Power failure triggers auto-open to 2,000 mm
    height for counterweighted doors (optional)
    • Transparent window (not available for cold storage)
    • Flashing light
    • Siren (optional)

    Help us to specify the project for you, by submitting the form below

    Protection with aesthetic values.
    Heavy-duty rolling shutter doors for normal temperature warehouses, providing a high level of security and protection.

    TECHNICAL SPECIFICATION Roller Shutter Door

    WIDTH (mm)

    2,000–12,000

    HEIGHT (mm)

    1,800–12,000

    SLAT THICKNESS (mm)

    0.6, 0.8, 1.0, 1.2 and 1.5

    SLATS

    Roll-formed first grade high-quality phosphated galvanised steel

    COATING

    Powder coated

    OPERATION

    Push button control

    40 mm/80 mm
    TP 40/TP 80

    For excellent insulation against the elements and temperature loss.
    • 25,000 operating cycles
    • Durable powder-coated springs

    TECHNICAL SPECIFICATION TP40 TP80

    MODEL

    TP 40

    TP 80

    PANEL THICKNESS (mm)

    40

    80

    HEATING ELEMENT

    N/A

    N/A

    Along side tracks

    WIDTH (mm)

    2,000–8,000

    2,000–6,000

    2,000–8,000

    HEIGHT (mm)

    2,000–8,000

    2,000–5,000

    2,000–5,000

    THERMAL INSULATION (R-VALUE) (m2. c/w)

    1.13

    2.3

    3.3

    WIND LOAD

    Class 2 (EN12424:2000)

    AIRTIGHTNESS

    Class 4 (EN12426:2000)

    WATERTIGHTNESS

    Class 3 (EN12425:2000)

    ACUSTIC INSULATION

    <35 dB

    DOOR PANEL WEIGHT (kg/m2)

    10.9

    16.3

    16.3

    THICKNESS OF STEEL CASING (mm)

    0.35

    TR EX

    For moderate-to-high traffic indoor or outdoor environments.
    • 1,500,000 operating cycles
    • 6,000 x 5,800 mm max size
    • Galvanised steel door structure & drive shaft

    TECHNICAL SPECIFICATION TR EX

    WIDTH (mm)

    2,000–6,000

    HEIGHT (mm)

    1,800–5,800

    OPENING SPEED (m/s)

    2.0 - size up to 3,000 x 3,000 mm
    1.5 - size up to 5,000 x 5,000 mm
    1.0 - size up to 5,800 x 6,000 mm

    CLOSING SPEED (m/s)

    0.8 or as opening speed

    FABRIC TYPE

    PVC coated polyester

    FABRIC WEIGHT (g/m2)

    900

    PANEL TYPE
    (OPTIONAL)

    Vision, 1 mm thick transparent PVC

    TRACK GUIDES

    Extruded polyethylene

    WIND LOAD

    EN12424:2000
    • Class 3 (3,000 x 3,000 mm)
    • Class 2 (5,000 x 5,000 mm)
    • Class 1 (5,800 x 6,000 mm)

    OPERATING TEMPERATURE RANGE (°C)

    • -15 to +70, indoor drive
    • -5 to +70, outdoor drive
    • -35 to +70, drive & side frame heating systems

    CONTROL UNIT

    • Painted steel housing, 470 x 290 x 200 mm
    • IP54 ingress protection; frequency converter

    OPERATOR

    Supply 240V/50–60Hz; 400V/50–60Hz;
    1.5kW motor power
    • IP54 ingress protection
    • Limit positions by encoder

    SAFETY

    • Built to EU standards - EN 13241 CN
    • Photocells (1 pair), 500 mm from floor level
    • Door bottom safety sensor
    • Power failure triggers auto-open to 2,000 mm
    height for counterweighted doors (optional)
    • Transparent window (not available for cold storage)
    • Flashing light
    • Siren (optional)

    Food Industry TR FO

    For food processing industries.
    • 1,500,000 operating cycles
    • 4,000 x 4,000 mm max size
    • Stainless steel AISI 304 door structure & drive shaft
    • Washable door & track

    TECHNICAL SPECIFICATION TR FO

    WIDTH (mm)

    2,000–4,000

    HEIGHT (mm)

    1,800–4,000

    OPENING SPEED (m/s)

    1.9

    CLOSING SPEED (m/s)

    0.8 or as opening speed

    FABRIC TYPE

    PVC coated polyester

    FABRIC WEIGHT (g/m2)

    900

    PANEL TYPE
    (OPTIONAL)

    Vision, 1 mm thick transparent PVC

    TRACK GUIDES

    Extruded polyethylene

    WIND LOAD

    EN12424:2000
    • Class 3 (3,000 x 3,000 mm)
    • Class 2 (4,000 x 4,000 mm)

    OPERATING TEMPERATURE RANGE (°C)

    • -15 to +70, indoor drive
    • -5 to +70, outdoor drive
    • -35 to +70, drive & side frame heating systems
    • Below -5, no windows

    CONTROL UNIT

    • Painted steel housing, 470 x 290 x 200 mm
    • IP54 ingress protection; frequency converter

    OPERATOR

    Supply 240V/50–60Hz; 400V/50–60Hz; 1.5kW motor power
    • IP54 ingress protection
    • Limit positions by encoder

    SAFETY

    • Built to EU standards - EN 13241 CN
    • Photocells (1 pair), 500 mm from floor level
    • Door bottom safety sensor
    • Power failure triggers auto-open to 2,000 mm height for counterweighted doors (optional)
    • Transparent window (not available for cold storage)
    • Flashing light
    • Siren (optional)

    Cold Storage TR FR

    Perfect for freezing conditions.
    • 1,500,000 operating cycles
    • 3,500 x 4,000 mm max size
    • Galvanised steel door & drive shaft

    TECHNICAL SPECIFICATION TR FR

    WIDTH (mm)

    2,000–3,500

    HEIGHT (mm)

    1,800–4,000

    OPENING SPEED (m/s)

    1.5

    CLOSING SPEED (m/s)

    0.8 or as opening speed

    FABRIC TYPE

    PVC coated polyester

    FABRIC WEIGHT (g/m2)

    900

    PANEL TYPE
    (OPTIONAL)

    Vision, 1 mm thick transparent PVC

    WIND LOAD

    EN12424:2000
    • Class 1 (3,500 x 4,000 mm)

    OPERATING TEMPERATURE RANGE (°C)

    • -15 to +70, indoor drive
    • -5 to +70, outdoor drive
    • -35 to +70, drive & side frame heating systems
    • Below -5, no windows

    CONTROL UNIT

    • Painted steel housing, 470 x 290 x 200 mm
    • IP54 ingress protection; frequency converter

    OPERATOR

    Supply 240V/50–60Hz; 400V/50–60Hz; 1.5kW motor power
    • IP54 ingress protection
    • Limit positions by encoder

    SAFETY

    • Built to EU standards - EN 13241 CN
    • Photocells (1 pair), 500 mm from floor level
    • Door bottom safety sensor
    • Flashing light
    • Siren (optional)

    Large Doors
    TR LA

    For large openings or high wind loads.
    • 1,000,000 operating cycles
    • 12,000 x 7,000 mm max size
    • Galvanised steel tracks, covers & tubes

    TECHNICAL SPECIFICATION TR LA

    WIDTH (mm)

    2,000–12,000

    HEIGHT (mm)

    2,000–7,000

    OPENING SPEED (m/s)

    1.0 - size up to 5,000 x 5,000 mm
    0.6 - size up to 12,000 x 7,000 mm

    CLOSING SPEED (m/s)

    0.5

    FABRIC TYPE

    PVC coated polyester

    FABRIC WEIGHT (g/m2)

    900

    PANEL TYPE
    (OPTIONAL)

    Vision, 1 mm thick transparent PVC

    OPEN/CLOSE MECHANISIM

    Belt system

    WIND LOAD

    EN12424:2000
    • Class 4 (up to 3,000 mm width)
    • Class 3 (up to 5,000 mm width)
    • Class 2 (up to 8,000 mm width)
    • Class 1 (up to 12,000 mm width)

    OPERATING TEMPERATURE RANGE (°C)

    • -15 to +70, indoor drive
    • -5 to +70, outdoor drive
    • -35 to +70, drive & side frame heating systems
    • Below -5, no windows

    CONTROL UNIT/OPERATOR

    • Supply 240V/50–60Hz; 400V/50–60Hz; 0.75–2.2kW motor power
    • IP54 ingress protection
    • Limit positions by encoder

    SAFETY

    • Built to EU standards - EN 13241 CN
    • Photocells (1 pair), 500 mm from floor level
    • Door bottom safety sensor
    • Power failure triggers auto-open to 2,000 mm height for counterweighted doors (optional)
    • Transparent window (not available for cold storage)
    • Flashing light
    • Siren (optional)

    TR SP

    For better security including residential usage.
    • 3,000,000 operating cycles
    • 6,000 x 6,000 mm max size
    • High wind load tolerance than standard high speed doors at certain sizes

    TECHNICAL SPECIFICATION TR SP

    WIDTH (mm)

    2,000–6,000

    HEIGHT (mm)

    1,800–6,000

    OPENING SPEED (m/s)

    1.5

    CLOSING SPEED (m/s)

    0.8 or as opening speed

    DOOR STRUCTURE

    Galvanised steel

    PANEL TYPE

    Aluminium sandwich panels

    SANDWICH PANEL THICKNESS (mm)

    40

    TRACK GUIDES

    Aluminium

    WIND LOAD

    EN12424:2000
    • Class 3 (3,000 x 3,000 mm)
    • Class 2 (6,000 x 6,000 mm)

    OPERATING TEMPERATURE RANGE (°C)

    • -15 to +70, indoor drive
    • -5 to +70, outdoor drive
    • -35 to +70, drive & side frame heating systems
    • Below -5, no windows

    CONTROL UNIT

    • For servo motor
    • Painted steel housing, 370 x 250 x 135 mm
    • IP54 ingress protection

    OPERATOR

    • Supply 240V/50–60Hz; 400V/50–60Hz; 0.75–1.5kW servo motor
    • IP54 ingress protection

    SAFETY

    • Built to EU standards - EN 13241 CN
    • Photocells (2 pairs), 400 mm & 900 mm from floor level
    • Door bottom safety sensor
    • Winter auto-run function
    • Partial opening function
    • Flashing light
    • Siren (optional)

    Full Vision TP VI

    For good insulation, allowing full light and vision through the door.
    • 25,000 operating cycles
    • Internal & external visibility
    • Good light permeability, energy saving

    TECHNICAL SPECIFICATION TP VI

    WIDTH (mm)

    2,000–6,000

    HEIGHT (mm)

    2,000–6,000

    THERMAL INSULATION (R-VALUE) (m2. c/w)

    0.20

    WIND LOAD

    Class 2 (EN12424:2000)

    WATERTIGHTNESS

    Class 3 (EN12425:2000)

    WEIGHT OF DOOR LEAF (kg/m2)

    17

    TYPE OF VISION PANEL

    40

    TRACK GUIDES

    Double acrylic glass

    ACRYLIC GLASS THICKNESS (mm)

    3

    WEIGHT OF VISION PANEL (kg/m3)

    3.28

    LIGHT TRANSMISSION TD65

    80 %


    Based on your selection, we recommend to add a loading bay shelter


    Retractable

    TS RE

    For air-conditioned and ambient temperature environments.
    • Double-reinforced PVC front cover
    • 0.5 mm thick PVC sheet side covers
    • Aluminium frame structure

    TECHNICAL SPECIFICATION TS RE

    WIDTH (mm)

    3,000/3,200/3,400

    HEIGHT (mm)

    3,000/3,200/3,400/3,800/4,400

    DEPTH

    600

    UPPER FLAP LENGTH (mm)

    1,000

    SIDE FLAP LENGTH (mm)

    600

    FRONT PVC SHEET THICKNESS (mm)

    3

    SIDE PVC SHEET THICKNESS (mm)

    0.5

    OPEN/CLOSE MECHANISIM

    Belt system

    OPERATING TEMPERATURE RANGE (°C)

    -35 to +50


    Inflatable

    TS IN

    Inflatable seal made for cold storage facilities where impeccable sealing is required.
    • Military-grade Cordura® 1000D inflatable cushions
    • 3-phase 380V 350W blower motor (1-phase 220V option available)
    • Sandwich panel frame

    TECHNICAL SPECIFICATION TS IN

    WIDTH (mm)

    3,410/3,610

    HEIGHT (mm)

    3,300/3,800/4,900

    DEPTH

    800

    UPPER CUSHION (mm)

    900

    SIDE CUSHION (mm)

    600

    CORDURA® 1000D CUSHION MATERIAL THICKNESS (mm)

    0.5

    AVERAGE CUSHION INFLATION TIME (sec)

    40

    OPERATING TEMPERATURE RANGE (°C)

    -35 to +50


    Compression

    TS CO

    For air-conditioned environments.